Ts0601 calibration manual I could pair it via ZHA, but i didn’t get any entities for controlling it Hi everybody! Invalid modes mode: manual baldisos I need some assistance to get more familiar with automation of my heating valves TS0601. Calibration of the sensor is also available Saved searches Use saved searches to filter your results more quickly Contents hide 1 Moes ZHT-006 Zigbee Smart Thermostat 2 (Floor sensor is Optional) 3 FEATURES 3. Could we reopen this issue @Koenkk? Perhaps I can give it a try to implement the state_topic and calibration option, but my This blueprint uses an external temperature sensor to calibrate a Zigbee TS0601 which is connected to Zigbee2MQTT. Adding your device. 5 . As an example, the thermostats are set to 15 degrees in automatic mode. These are two devices with identical PM2. Output from Home Assistant Device Diagnostic from BT { "home_assistant": { It’s a TS0601 type, the manufacurer name is “_TZE200_i48qyn9s”. How to use device type specific configuration. You switched accounts on another tab or window. I want to use external temperature sensor to calibrate thermostat (using local_temperature_calibration value) when [Device Support Request] MOES Zigbee 006 Thermostat Model TS0601 manufacturer_TZE204_aoclfnxz #2433. Model link for reference: Hi, has anyone an idea how to set the local_temp_calibration via zha? Problem: The temperatur from my Moes BHT-002GCLZB alias TS0601 _TZE200_aoclfnxz is about 2. The value must be a number. You can solder fixed resistor Integrate your TuYa TS0601_smart_air_house_keeper via Zigbee2MQTT with whatever smart home infrastructure you are using without the vendor's bridge or gateway. The minimal value What happened TS0601_thermostat calibration does not support negative values What did you expect to happen Setting negative value to calibrate in negative direction. climate device supports the following features: preset, current_heating_setpoint, local_temperature, local_temperature_calibration, system To control publish a message to topic zigbee2mqtt MOES Smart Thermostatic Radiator Valve ZigBee LCD Curved Screen Heating Battery Powered TRV TS0601. I would l Problem description Hello I have problems with zha to get the correct attributes for my (Tuya) TRV TS0601 from _TZE200_b6wax7g0 to get. How to reproduce it (minimal and precise) No response. 11 and i very likely the same function on the other tuya TRVs (reusing code and hardware make it cheaper). py with _TZE200_p3dbf6qs. The text was updated successfully, but these errors were encountered: [0xf64f] Discovered basic device information for Hello, HA community. 5C) temperature, as external temperature sensor using It is slightly different from the ones previous found in the Blueprint section of the Home Assistant forum, since those expect the \"local_temperature_calibration\" attribute to be part of the TS0601 entity itself. I ask for some further support to get the sensor ‘out of the box’ ready. image 874×765 54. You signed out in another tab or window. It is slightly different from the ones previous found in the Blueprint section of the Home Assistant forum, since those expect Winter is coming and you don't need to be John Snow to see it. _local_temperature_calibration: -6. Could that be the problem? What did you expect to happen It to pair successfully How to reproduce it (minimal and p. Let start with showing you the basic settings I have it set up with. Creating own quirk based on ts0601_sas. Can't I connect this product to HE via Matterbridge? Summary. Reload to refresh your session. local_temperature_calibration is avaible via MQTT but it's not exposend as value in Homeassistant. I publish a short ‘how-to’ to outline the steps to get the sensor to work. For this reason, I do not think this is a device limitation. First, if we don't have 'heat' only, it will expose all system modes by default. Instructions 1. The device reports it’s temperature and moisture readings, as well as battery percentage. What version of Home Hey, i would like to use a script to sync the local_temperature_calibration to an external temperature sensor in Home assistant. Manual, OFF, Auto, ON: 2: x: x: x: rtitekHeatingSetpoint: Set temperature: 15. fr, Qiumi brand) to install in my I recently bought a garage door opener from aliexpress. Doing this I now have the positions correct. Manual or automatic if possible. TS0601: Endpoint 01 outClusters: 0019,000A: Endpoint 01 profileId: 0104: Endpoint 01 stage: 4: image 830×342 21. 7, After a while, reports another value. voltage_calibration: Calibrates the voltage value (percentual offset), takes into effect on next report of device. 5 C° to high. Edit 1 - 27/08/2024 - Updated code block with fix for Im running openHAB 2. While pairing, keep the valve close to the coordinator. Wire the L-Live wire to the L-Terminal 2. 0-2. But when i try to an automatic I assume that with TS0601 you mean this TRV shown in the link? I am afraid to understand that the only way to use this model is an all/ nothing mode based on manual+heat or manual+off un case of usage of BT thermometers measuring over some days. current_heating_setpoint : This climate device supports the following features: current_heating_setpoint, local_temperature, system_mode, local_temperature_calibration, preset, running_state. I choose to go for zigbee2mqtt to connect some Tuya TherTS0601_thermostat with my openHAB stamrt home. temperature_calibration: Calibrates the temperature value (absolute offset), takes into effect TS0601_soil: Vendor: Tuya: Description: Soil sensor: Exposes: temperature, soil_moisture, temperature_unit, battery, battery_state, linkquality: Picture: Options. Zigbee2MQTT version. The only thing this component was supposed to do was adjust the calibration if device supports it. Home Assistant 2021. 5 Frontend 20230202. "local_temperature_calibration": 6551. Low Battery. 2021-10-30 05:58:50 -0700. Contribute to jacekk015/zha_quirks development by creating an account on GitHub. If you haven't figured it put yet then a couple things I've noticed with the same TRV: the valve opened percent is never correct, only gets updated after you change the temperature from the TRV directly; there's a binary sensor saying These sensors need some kind of individual calibration. The zigbee specification says an 8-bit int and the valid range is 0xE7 - 0x19 so -2. On the lovelace it works pretty good. If I add "_TZE200_dzuqwsyg", to. Third message in a row, I’m terribly sorry! I’ve got something! I added a couple of class (TuyaMmwRadarClusterV4 and , TuyaMmwRadarOccupancyVariant4) based on that github issue. 3 Hi, i have zigbee2mqtt running on my Raspi. [TS0601_thermostat] This blueprint allow to calibrate them to have same (± ~0. Calibration can be done manually by pressing and holding pause button until it start blinking then press open and wait the time needed then press open again. Zigbee2MQTT. Contribute to X4LD1M0/HA-Blueprint-TS0601-Calibration development by creating an account on GitHub. What did you expect to happen? Valve returns to previous mode after boost time expires. Invalid value for number. It is correctly identified as an EndDevice with Zigbee Model TS0601 and Manufacturer _TZE200_myd45weu. In Home Assistant Lovelace UI it shows all possible modes. current_heating_setpoint, local_temperature, local_temperature_calibration), deadzone_temperature, lock (state), schedule_monday, schedule_tuesday, schedule_wednesday, schedule_thursday All quirks in one place. After a week of learning I fo A wiring diagram is included in the Manual: 1. (one thermostate to rule Options. MODE 1 (actually it's Preset - auto, manual, off, on) - auto is schedule setup, manual is manual, off is off, and on is constant on regarless of the temperature setting. 0 - latest I’ve added the TS0601 TRV to the Zigbee controller and can see it, thermostat functions look like they’re working and I can control the valve. However, CHILD_LOCK and TEMP_CALIBRATION don't seem to do anything. The problem is not present on a Avatto ME167 TRV using the ts0601_trv_me167. Ventilation and energy saving:ventilation and energy saving function is default off, if you want to open this function, please set in advanced options(The default settings will be restored when the battery is replaced ) Children lock; Open Window function Using the remote you can change the direction of the curtain, which will also invert in HA. ; Select WiFi settings: Press the plus button ( ) button 4 times to see the digital 5 on the right hand side and the blinking WiFi logo. 2. voltage_precision: Number of digits after decimal point for voltage, takes into effect on next report of device. It is bugged for sure, not sure how @KartoffelToby intended this to work since there is no documentation. TUYA_THERMOSTAT_MANUFACTURER = (in Modules/tuya. This climate device supports the following features: local_temperature, current_heating_setpoint, local_temperature_calibration, preset, system_mode, MANUAL MODE ☝ - In this mode, the Meanwhile I have found a workaround. Open bsfaxi opened this issue Jun 15, 2023 · 125 comments switch between manual and schedule; set program schedule day by day; switch off TS0601_scenario_log. dev1301 Operating System 9. 0 (range -5. It is slightly different from the ones previous found in the Blueprint section of the Home Assistant forum, since those expect the "local_temperature_calibration" attribute to be part Calibrate Zigbee TS0601 in Home-Assistant. I went with the TS0601 TRVs after seeing the review from the Bearded Tinkerer and finding them at a reasonable price point. I wanted Zigbee rather than loads of wifi devices. A calibration option to tweak the open/close threshold could solve the incorrect state. Tested on TS0601 radiator valve with thermostat, but most probably will work on similar products from TuYa 7 Likes andrewvol (Андрей Волгунов) September 30, 2021, 10:47am Options. 5 friendly_name: Bedroom The print history shown below lists the printing dates of all Revisions and Addenda created for this manual. Problem description I bought some Zigbee TRVs, they show up in home assistant as TS0601_TZE204_pcdmj88b but although they are pairing, no entity for control or sensor reading is showing up. -running 5x TS0601 (perhaps the manufacture company is important: _TZE200_c88teujp) (z2m link to this device) Setup ZHA device handlers bridge the functionality gap created when manufacturers deviate from the ZCL specification, handling deviations and exceptions by parsing custom messages to and from Zigbee devi Hi, I have the TRV TS0601 "TZE200_hue3yfsn" that are kinds of Tuya. What was sent to HA. Unfortunatelly, it didn't work out of the box with HA using ZHA. Hi @w35l3y The driver works, but I am missing some off the available datapoints. MmwRadarMotion” Which is fine, as in it works, but there is no I'm running into this problem with my Tuya TS0601 curtain motor as well. data. Options. @ranko-ha Without official doc's you can only guess or, someone with the Thermostat need to enable debug logging and do test's, mark test time, and the post the logs. Once you apply it, the device will be identified as model TS0601 and manufacturer _TZE204_cjbofhxw and custom MOES TS0601 Smart Radiator Thermostat User Manual MOES TS0601 Smart Radiator Thermostat Many thanks for your selection of our products and services, and also for your trust and support to us. 7 installation_type Home Assistant OS dev false hassio true docke ZHA device handlers bridge the functionality gap created when manufacturers deviate from the ZCL specification, handling deviations and exceptions by parsing custom messages to and from Zigbee devi For Siterwell GS361A is briefly described in the manual 5. This option can only decrease the precision, not increase it. Tested on TS0601 radiator valve with thermostat, but most probably will work on similar products from TuYa Integrate your Tuya TS0601_thermostat via Zigbee2MQTT with whatever smart home infrastructure you are using without the vendor's bridge or gateway. Hello Guys, What i have figure out after carefully went thru manual is that this TRV has 3 regulation options ( in my version in menu under A) 0: PID - when i selected this TRV is opening/closing valve in increments of 5, what seems to be quite nice and dense regulation, unfortunately, it is not closing valve even when the What happened I paired a new TS0601_thermostat but it says Manufacturer "UNSUPPORTED" On the package it says Model HY368. MQTT State Topic: zigbee2mqtt/TRV1 MQTT Command Topic: zigbee2mqtt/TRV1/set the information JSON string comes in, but the JSONPATH Saved searches Use saved searches to filter your results more quickly Calibration. valve. Turn the display on: Short press home (🏠). I'm based in Scotland. 5 temperature: 25. Get startedDown. Like it often happens, the packing was banged up but the device intact. Temperature calibration can not set to values higher than a delta of 3 degrees. Ha, latest version. In order to toggle the relay manually do a triple press on the button. temperature_precision: Number of digits after decimal point for temperature, takes into effect on next report of device. By default it takes this quirk: “zhaquirks. 5. If it averages on the same value, good, If not find the setting for temperature calibration Integrate your Tuya TS0601_floor_thermostat via Zigbee2MQTT with whatever smart home infrastructure you are using without the vendor's bridge or gateway. power_calibration: Calibrates the power value (percentual offset), takes into effect on next report of device. The Tuya Soil Plant Sensor GXM-01 is supported in ZHA too, automatically enabled with a custom quirk: tuya. 16 the battery indicator disappears,% flashes in its place What happened What did you expect to happen How to reproduce it (minimal and precise) Debug info Zigbee2 Saved searches Use saved searches to filter your results more quickly Tuya TS0601 TRV . TuyaSoilSensor. 5 preset_modes: none, schedule, manual, boost, complex, comfort, eco current_temperature: 22. According to the product manual, there is a programmable mode, but the different "days of the week" i've tried, dont read or write correctly. However there are a few switches and functions that don’t have labels and I Tuya 4in1 PM Box (Smart Air box) with CB3S module (Wi-Fi) on the left (blue case) and Tuya 6in1 Air House Keeper with ZT3L module (Zigbee) on the right (white case). Please add support or fix the problem with TRV from Tuya TS0601 _TZE200_hue3yfsn #3142. MoesBHT” shows under Hi all, I am trying te read out the local_temperature value from the TuYa TS0601 valve. Integrate your Tuya TS0601_din via Zigbee2MQTT with whatever smart home infrastructure you are using without the vendor's bridge or gateway. txt; Anyone can help please? All reactions. Hi, I am using radiator thermostat MOES HY369RT that are presented in Z2M assistant as TS0601. You can pair this device by setting device to manual mode by short press rotary button (until clock symbol is not displayed), setting temperature to "OF" by rotating left, then press and hold If you are using z2m in docker, you need to uncomment the lines: const dp = msg. Prerequisites Model name of your Devices - TS0601 - TZE200_cpmgn2cf Output from Home Assistant Developer Tools state e. But I have the Problem that with the Better Thermostat Integration at the Configuration step which calibration typ I will have I only can choose Target Temperature. As I have no manual for this TUYA TS0601_thermostat I don't know if there is such a thing What happened Action and valve_detection properties are described in HA config topics, but missing in state. Oddiwahn mentioned this issue Nov 4, 2021. Adding to Home Assistant Home Assistant screen with TRV controls Platform information: raspberry Pi 4 openHAB version: 3. 3 KB. energy_precision: Number of digits after decimal point for energy, takes into effect on next report of device. The manual explains that the valve has its own algorithm and you can disable it by setting it to 1. datatype, msg. I can see the actual temperature and can steer the temperature that the thermostat should heat. energy_calibration: Calibrates the energy value (percentual offset), takes into effect on next report of device. 41. 5 to +2. Is there already a zha_quirks for this thermostat? Many many Thanks Solution description I have resea Saved searches Use saved searches to filter your results more quickly This is an issue for collecting feedback for normal calibration for TS0601. 5 and then it is okay. temperature_calibration: Calibrates the temperature value (absolute offset), takes into effect on next report of device. Closed Copy link Contributor In the included manual it's refered to as TV02 Zigbee Thermostat Radiator Valve I bought it from this link: AliExpress. That's only 100% method. Integrate your Tuya TS0601_din_4 via Zigbee2MQTT with whatever smart home infrastructure you are using without the vendor's bridge or gateway. As @KartoffelToby suggested, I'm opening an issue for collecting feedback for the normal You signed in with another tab or window. from zigbee2mqtt. Update your z2m configuration. reserves the right to revise this information at any time and for I read somewhere that it does the calibration automatically. WCaution The 789 ProcessMeter contains parts that First I set local_temperature_calibration to -1,7 "local_temperature_calibration": -1. hvac_modes: - heat - 'off' min_temp: 5 max_temp: 35 target_temp_step: 0. It works with ZHA pretty well but ZHA doesn’t support two features that I need: Temperature offset (calibration) Deadzone temperate setting. Screenshots/Video kulisau changed the title [Device Support Request] TS0601 by _TZE204_guvc7pdy [Device Support Request] TS0601 by _TZE204_guvc7pdy Moes Curtain motor May 21, 2024. 1. 5/PM10 sensors (boxes with the metal cover), temperature and humidity sensors (top center) which are connected to an STC 8G1K08 microcontroller which Hello, there is a problem with tuya TS0601_thermostat after updating to 1. I know it looks odd, but there are 2 reasons for that. It says 100 (open) when my curtains are indeed open and 0 (closed) when my actual curtains are closed as well. If you look at the device itself, the value of “Local temperature calibration” will be completely different. I need your help. But there I set an offset from -2. 0 commit TLDR - I bought a sensor, realised it didn’t work and spent a small fraction of my life getting it to work. The ranges needs to be adjusted, but the every parameters seems to be working fine (even the Illuminance, that was previously Unavailable). Now I want to heat to 19 degrees. dp; const value = tuya. The Revision Level letter increases alphabetically as the manual undergoes s ubsequent updates. The device packaging lists the manufacturer as Ecobuy smart controls Co Ltd, and the model The problem I would like to set local_temperature_calibration in the ui and use it with my automations, but it's not there In the Mqtt-data from Zigbee2Mqtt it can be found. This can be seen in the logs by the discrepancy between “Local temperature calibration” and “Local temperature” Integrate your Tuya TS0601_air_quality_sensor via Zigbee2MQTT with whatever smart home infrastructure you are using without the vendor's bridge or gateway. The exact device model is: TS0601 - _TZE204_ztc6ggyl. MoesHY368_Type1, the one ZHA device handlers bridge the functionality gap created when manufacturers deviate from the ZCL specification, handling deviations and exceptions by parsing custom messages to and from Zigbee devi When I change the temperature calibration of the device, the local temperature is not updated accordingly. Integrate your Emos P5630S via Zigbee2MQTT with whatever smart home infrastructure you are using without the vendor's bridge or gateway. 5C) Local temperature Integrate your Tuya TS0601_thermostat_1 via Zigbee2MQTT with whatever smart home infrastructure you are using without the vendor's bridge or gateway. Hi there, Currently I am trying to get custom quirks working for a Tuya motion sensor (mmWave and illuminance. Today I'll install and integrate in Home Assistant Tuya based Moes Zigbee Smart radiator valve koenkk > zigbee2mqtt TS0601 - zhc: Failed to apply calibration to 'voltage' and 'power' about zigbee2mqtt HOT 5 CLOSED prohand commented on December 29, 2024 TS0601 - zhc: Failed to apply calibration to 'voltage' and 'power'. 6 KB. ) I bought a dozen of these TRV (on Amazon. The code is now more appropriate for the device and has more functionality. The value must be a number. From the logs, using time, you can guess what attribute was modified. 0) I have couple of _TZE200_hue3yfsn TuYa TRV's on which I set the local_temperature_calibration trough HA automation every 20 min based on external temp sensors, trough this calculation which value is send as payload to the corresponding MQTT topic: Support new Tuya devices. Before switching to ZHA, I was using zigbee2mqtt and the issue was not present. Connection to openhab works, connected trv Avatto ME 167 (Tuya TS0601) is seen by openhab. . I found the ASNNetworks changed the title New manufacturer TuYa TS0601_thermostat (_TZE200_ywdxldoj) New manufacturer TuYa TS0601_thermostat Feb 4, 2021 Copy link 877dev commented Feb 5, 2021 • Hello, I got same French valves by Thaleos-Connect, I have following definition : const definition = { zigbeeModel: ['TS0601'], model: 'TS0601', vendor: '_TZE200 Integrate your Tuya TS0601_din via Zigbee2MQTT with whatever smart home infrastructure you are using without the vendor's bridge or gateway. Integrate your Tuya TS0601_thermostat_2 via Zigbee2MQTT with whatever smart home infrastructure you are using without the vendor's bridge or gateway. What does/doesn't work with the external definition? Works: Child lock state Current heating setpoint (but only in 1C step, not 0. (Auto/Manual Mode) AND right button (Comfort/Energy Saving Mode) until "Zigbee connection status"-light (the wifi icon) flashes {"local_temperature_calibration": VALUE}. 5 on pi I have some TRVs I need to add via ZigBee2mqtt there are the ones I’ve added the temperature reading and getting with ease but stumped with the mode setting because there is more than one two options so standard switch doesn’t work modes: - “off” - “auto” - “heat” - “manual” Hello, (I didn't know where I should post, so feel free to merge with the relevant subject if there is one in particular, maybe in the discussions, I don't know. I remember in the native app it was possible to set a delta of 5 degrees. I have one TRY im my bath that never need heating so its no problems and on in the kitchen that is doing much heating and have getting jammed 2 times in the winter and one more on the lab table Page 2 323/324/325 Calibration Manual Safety Information A Warning identifies conditions and procedures that are dangerous to the user. Both have an radiator with TS0601 installed. At the moment TS0601 uses target temperature calibration, because of the reasons discussed in #41. However, the quirk for Moes thermostats says it’s attribute 0x022C and defines it as a 32 bit int and the quirk maps the local_temperature_calibration attribute to the moes attribute. when I first tested a Siterwell TRV there were quite a few steps in a specific order one needed to do for a first calibration. die Logs aus HA helfen hier nicht, da wir uns hier im Z2M befinden, hier muss das gemacht werden. earch for “Smart Life” Download the Wifi App with the following icon For other languages, please scan the QR code above. But the TRV supports up to 10 degrees. I bought a BHT-002-GCLZB thermostat [recognized as (“_TZE200_u9bfwha0”, “TS0601”) model]. the ones that work had manufacturer _TZE200_ckud7u2l and quirk zhaquirks. A Caution identifies conditions and procedures that could cause Product damage, equipment under test damage, or permanent loss of data. Addenda, which are released between Revi-sions, contain important change information that the user should incorporate immediately into the Hello, using conbee2 on Raspberrypi, zigbee2mqtt latest version - Current version: 1. 2022-06-20 05:58:50 -0700. Good day, thermostatic head does not form in domoticz Setup, Devices, new IDX only one entry: 512 zigbee api_transport 255 zigbee - Zigbee2MQTT API Transport General Text {"type": "response", "requ You signed in with another tab or window. TARGET TEMP 2 CURRENT TEMP 3 WORKING STATUS 6 WINDOW STATUS 7 OPEN WINDOW 8 CHILD LOCK 12 BATTERY 13 FAULT ALARM 14 MIN LIMIT TEMP 15 MAX LIMIT TEMP 16 EDIT: Oh cool, some people seem to have figured out the commands in the comments on this zigbee2mqtt GitHub issue: TS0601 _TZE200_fzo2pocs (Zemismart ZM25TQ) - position and motor speed issue · Options. developed for it. Page 1 CS660/CS661 Spreader Controller Calibration Manual; Page 2: Table Of Contents Appendix – CS-660 System layout, Cable Drawings Bosch Rexroth Canada Corp. Manual toggle. This just doesn't work, not sure what the read property would be for this. Hey Hassiors, i now have 3 Tuya thermostats installed and all three have the problem that when they heat, they don’t stop at the target temperature. Just to be sure, we are talking about this one : Neo Temperature, Humidity and Illumination Sensor (NAS-TH02B) Zigbee Prerequisites Model name of your Devices Moes TS0601 Output from Home Assistant Developer Tools state e. The device TS0601 _TZE200_g9a3awaj has no support in Quirks. ts0601_motion. Personally, I've been using normal calibration just fine (by editing source files of this integration). Until recently I have used regular TRVs with a pretty big Bosch boiler 40kw that feeds 24 radiators over three floors. getDataValue(msg. In order to enter pairing mode, hold the Tuya radiator valve (TS0601) calibration from external sensor (via zigbee2mqtt) Advanced users of this valve can make upgrade to control valve position without any temperature calibrations . power_calibration: Calibrates the power value (percentual offset), takes into effect on next report of device Problem description I have a Tuya-based ZigBee thermostat purchased from Aliexpress. invert_cover: Inverts the cover position, false: open=100,close=0, true: open=0,close=100 (default false). holiday mode, press to choose manual or auto mode then exit. Do not perform the calibration verification tests or calibration procedures described in this manual unless you are qualified to do so. Sign in Product Actions Brennstuhl Connect (TS0601) add attribute "local_temperatur_calibration" (0x0010) #2149. Adding support for 187/189 Calibration Manual Replacing the LCD If you need to replace the LCD, you will find it easier to leave the LCD assembly attached to the circuit board and access the LCD by removing the LCD mask from the front of the LCD assembly. I have it connected via zigbee2mqtt and can control it with the generic thermostate. temperature_calibration: Calibrates the temperature value (absolute offset), takes into effect Options. Solution description. g. The device came packed in a neat little box containing the sensor itself and a user manual, nothing else. js Datei. Ventilation and energy saving:ventilation and energy saving function is default off, if you want to open this function, This climate device supports the following features: current_heating_setpoint, local_temperature, system_mode, running_state, local_temperature_calibration. Read through basic howto for instructions on how to setup an external converter. Closed DLieb opened this issue Jan 29 Hi all, Using the Zigbee Home Automation on my HA 2023. Closed JuMi2006 opened this issue Feb 22, 2023 · 9 comments Closed In the included manual it's refered to as TV02 Zigbee Thermostat Radiator Valve I bought it from this link: AliExpress. With other sensors (like esphome sensors) I have the same problem. They are working with the ZHA integration. 02. 2. Log says: [0x875F:1:0xef00] Unknown cluster command 2 b’\\x You can also download and refer to the previous app version. I would like share what I have been able to figure out for the MOES Thermostat Radiator Valve (TRV) I order 6 from Aliexpress and out of all 6 only one was recognized. Hello, I was looking into buying this sensor also, good thing I made a little research before. 0 - 5. TS0601_thermostat_1: Vendor: TuYa: window, alarm_switch, climate (local_temperature, current_heating_setpoint, local_temperature_calibration, preset, system_mode, running_state), schedule_monday, schedule_tuesday, schedule_wednesday, schedule_thursday, schedule_friday, schedule_saturday, schedule_sunday, boost_heating, boost_time With the target temp methot we lose the manual controlling on the thermostat itselfs because the displayed temp is not the real target, but i get your problem now with the TS0601, its possible that the BRT-100-TRV has the same one and i have one of these here now, so i will move the sort of "calibration" also to the model mapping, that we can have differend Integrate your Tuya TS0601_thermostat_4 via Zigbee2MQTT with whatever smart home infrastructure you are using without the vendor's bridge or gateway. The room temperature is 17 degrees. 1 DIMENSION:(mm) 4 BEFORE WIRING AND INSTALLING 4. Apparently, it works out of the box with Zibgee2MTTQ, but I haven't tested that integration. 7 System Health version core-2021. This blueprint uses an external temperature sensor to calibrate a Zigbee TS0601 which is connected to Zigbee2MQTT. Page 21: Reassembling The Meter Case True RMS Multimeter Basic Maintenance Reassembling the Meter Case To \n. I have also found this reference on HA forum, where a user mentions the TS0601 valve, which is from another manufacturer but at the end of the day it's the same device. current_heating_setpoint DOWNLOAD MANUALS: MOES TS0601 Smart Radiator Thermostat User Manual. The zha quirks “electric_heating. 10. py. ; Enter WiFi settings: Press home (🏠) once again. Navigation Menu Toggle navigation. No success. Therefore, you should still be Integrate your BSEED BSEED_TS0601_cover via Zigbee2MQTT with whatever smart home infrastructure you are using without the vendor's bridge or gateway. 9, What did you expect to happen? local_temperature_calibration do not changes over time. Table 1 shows the symbols used on the Product and in this manual. How to reproduce it (minimal and precise) Trying to set calibration wit Problem description Tested with actual zha in home assistant. 22. Diesen aber nicht einfach hier stumpf "rein kopiert" (wie oben), sondern als Datei Anhang, also die . 00? 3: x: x: Some stuff like temperature calibration is still not working. For this project i want to read the local temperature from 3 valves in one (big) room, take the average temperature and use a “master” thermostate for all 3 thermostates. These are the missing datapoints I’ve tested with the generic driver that I know work: Setting Thermostat Mode (Enum 1, 0=Run Program, 1=Manual mode, 2=Temporary manual mode, 3= Holiday mode) Boost Heating (Boolean 4 = On/Off) Child lock (Boolean 13 = Lock/Unlock) Set Hi @Koenkk Unfortunately this is not ready, missing many settings: sensor, schedule, week, brightness_state, sound, frost_protection, factory_reset, heating_temp TS0601 by _TZE200_dfxkcots Zigbee info IEEE: 60:a4:23:ff:fe:ef:2b:75 Nwk: 0xc614 Device Type: Router LQI: 72 RSSI: Unknown Last Seen: 2021-04-18T17:57:47 Power Source: Mains Something going mismatch and logs keep repeating the same pattern: Can only set one temperature, if you need a week/daily cycle, you need to modify the automations or just modify the slider; Can only work with an good external temperture probe, which is properly installed, see installation temperature probe for help; there's no "get the heat on fast" for a very cold room (but the TRV should turn on the heat pretty quickly anyway, since there's a high Integrate your Tuya TS0601_thermostat_3 via Zigbee2MQTT with whatever smart home infrastructure you are using without the vendor's bridge or gateway. It often reports 1 or 2 instead of 0 and 97 instead of 100. yaml, the calibration TS0601_smart_air_house_keeper: Vendor: Tuya: Description: Smart air house keeper: Exposes: temperature, humidity, co2, voc, formaldehyd, pm25, linkquality: How to use device type specific configuration. 5 preset_mode: complex friendly_name: gabinet supported_features: 17 auto_lock: MANUAL away_mode: OFF away_preset_days: 1 away_preset_temperature: 18 The TRV has a setting only available in Zigbee2MQTT called "local_temperature_calibration" This allows you to add a temperature offset to allow for localised heating by the radiator or other heat sources. The text was updated successfully, but these errors were encountered: [0xf64f] Discovered basic device information for <Device model='TS0601' manuf='_TZE200_hue3yfsn' nwk=0xF64F ieee=50:32:5f:ff:fe:67:7a:76 is_initialized Saved searches Use saved searches to filter your results more quickly I bought 4x TS0601 Radiator TRVs the other day, 2 connected fine with all climate control options, 2 added but with no entities. data); holiday mode, press to choose manual or auto mode then exit. How to reproduce it (minimal and precise) set valve to manual and temperature of 24; switch to Boost mode hvac_modes: heat, auto, off min_temp: 5 max_temp: 35 target_temp_step: 0. Given Environment and Goals On the basement, I do have an open kitchen (living room and kitchen are same room). Hi, i integrated many devices in HA with ZHA and everything went fine. Nein, ich hätte gerne deinen Code oben, aus deinem erste Post, deinen "alten" converter der nicht mehr funktionierte. 4. MOES Smart Thermostatic Radiator Valve ZigBee LCD Curved Screen Heating Battery Powered TRV TS0601 SKU: Regular TuYa radiator valves measure temperate on themself, which gives inaccurate results. Control Type of Valve - 0: PID 1: ON/OFF. Climate config with action: {"action_template":"{% set Tuya TS0601_thermostat starts heating despite temp being over setpoint I am just starting with ZigBee. Comments (5) Koenkk commented on December 29, 2024 1 . Would like to get the device fully integrated into ZHA without custom quirks. Standard part of the setup. I found a few topics and I’m trying to add those features to my HA gui. The value must be a number with a minimum value of 0 and with a with a maximum value of 3. Now the valve opens however the temperature setpoint changes and the valve returns to "Schedule" preset instead of the mode it was originally in (Manual). All reactions went wrong. ; Enter settings: Long press home (🏠) for 3sec. tuya. But I cannot get the device to work with a custom quirk. Tuya devices use a custom manuSpecificTuya cluster, the instructions below will help you understand it better and provide some tools to ease discovery of their functions. 3 Supervisor 2023. 1 WIRING 5 INSTALLATION 6 OPERATION 7 The information provided in this manual is for the use of qualified personnel only. The value is 10x the offset you want. Hi everyone, I got one of those Tuya TS0601 _TZE204 “Presence” sensors but even after leaving the area the presence sensor detects occupancy for a very long time anyone know how to configure that ? I know on the “configure Zigbee device” page I have some properties but not sure what to put in there: Integrate your Tuya TS0601_GTZ10 via Zigbee2MQTT with whatever smart home infrastructure you are using without the vendor's bridge or gateway. It is slightly different from the ones previous found in the Blueprint section of the Home Assistant forum, since those expect the \"local_temperature_calibration\" attribute to be part of the TS0601 entity itself. The value must be TS0601_thermostat_2: Vendor: TuYa: Long press left button (Auto/Manual Mode) AND right button (Comfort/Energy Saving Mode) until “Zigbee connection status”-light (the wifi icon) flashes This climate device supports the following features: system_mode, preset, local_temperature_calibration, local_temperature, current_heating_setpoint. The value must Need some help getting a Tuya TS0601_thermostat to work. When i select "state" in the tab menu, i get the following: The quirk is missing the attribute for local temperature calibration Describe the solution you'd like Add attribute to cluster and Skip to content. ts0601_sensor. Now i tried to make my first automation with a TS0601 (Hysen Thermostatic Radiator Valve Controller HY368 Zigbee compatibility). Now only WiFi logo is showing without blinking. Guide Guide. TS0601 Attribute limits (temperature_calibration) #16783. The thermostats open completely and the heating quickly reaches When transferring the "Local temperature calibration" parameter, the data is sent to the device incorrectly. the device is now recognized as a thermostat and it is working somehow: the temperature, the The manual of my valve, says. otyf iaec gsqww utw yvsxn ivnnaix dpxqq znnj veghh rvioopy